HSMC2series
■50kPa~3MPa
■2 setting outputs + 4 to 20 mA(with analog output scaling function)
■Quick zero-adjustment, tracking zero adjustment, loop check and moving average are included as standard.
■Safe and reliable construction with break-proof diaphragm
■Safe and reliable construction with no sealed liquid.
Measured medium | Alcohols, milk beverage, seasoning, pure water, chemical or other media. (These vary according to sensor materials) |
---|---|
Pressure type | Positive and negative pressures can be measured. |
Pressure range | Can be specified within the range of 50 kPa to 3 MPa (Calibration:25kPa~3MPa) of rated capacity. |
Output type | 4~20mA(4 wire system) 2-point photo-Mos relay output. Specify more than 50% of rated capacity as the calibration range. |
Specification 1 (Sensor assembly)
Sensor Connection | ISO Ferrule, VARIVENT®, ISO Cap nut, Screw mount, Other special orders |
Rated Capacity(R.C.) | 50, 100, 200, 300, 500, 1000kPa, 3MPa |
Material | Sensor: SUS316L / Hastelloy C276 / SUS329J4L |
Finish(Sensor Part) | Electro-Chemical Buffing |
Safe Overload Rating | 400%R.C. (Rated capacity 3MPa: 150%R.C.) |
Destruction Point | 1000%R.C. (Rated capacity 3MPa: 300%R.C.) |
Specification 2 (Amplifier + Sensor assembly)
Non Linearity | ±0.5%R.C. |
Hysteresis | ±0.5%R.C. |
Compensated Temperature Range (Wetted part) | -5~150?C |
Safe Temperature Range (Wetted part) | -5~150?C |
Temperature Effect on Zero Balance | ±0.5%R.C./10?C (Rating: 300, 500, 1000kPa, 3MPa) |
±0.7%R.C./10?C (Rating: 50, 100, 200kPa) | |
Temperature Effect on Load | ±0.5%R.C./10?C (Rating: 300, 500, 1000kPa, 3MPa) |
±0.7%R.C./10?C (Rating: 50, 100, 200kPa) | |
Ambient Temperature and Humidity | Temperature:0~50?C(No freezing), Humidity:0~90%RH(No condensation) |
Material | Aluminum die-casting(Case material) Acrylic(Front) SUS304(Radiating fin) |
IP Rating | Equivalent to IP65 |
Mass | Standard: Approx. 960g (A sensor assembly is included. / In the case of ISO ferrule 2S) |
Accessories | Operation manual (1 copy), Test report (1 copy), 1 of connector for a power supply input 1 of connector for a setting output at an analog. (*1) |
(*1) Refer to Accessories Page for collectors.
Model Selection
Selection | Check | Model | Specification | |
---|---|---|---|---|
1.Model | ○ | HSMC2 | Intelligent model high temperature type: Temperature range of wetted parts -5~150?C | |
2.Output | ○ | 32P | 4~20mA(4 wire system)(Scaling enabled) + 2 settings photoMOS relay output (Combination of AC and DC, Load voltage: 240V, Load current: 120mA) Response:1~500time/sec. Synchronized with the sampling rate Hysteresis setting range: 0~999 | |
3.Casing type | ○ | AS | Sensor directly connected on bottom | |
4.Display/Calibration (*2) | - | - | Example of calibration range | |
Pressurization | (Example)Rated capacity At 100.0kPa100.0kPa (0~100.0)kPa | Specify the values and units of display/calibration ranges. | ||
Negative pressure | (Example)Rated capacity At 100.0kPa-101.3kPa (0~-101.3)kPa | In case of negative pressure, put the calibration range value in parentheses. | ||
Compound pressure | Compound pressure model not available. | |||
5.Rated Capacity(R.C.) | 005 | 50kPa | ||
010 | 100kPa | |||
020 | 200kPa | |||
030 | 300kPa | |||
050 | 500kPa | |||
100 | 1000kPa | |||
300 | 3MPa [Display/Calibration: Specify 3.00MPa] (Make to order) (Withstand pressure:150%R.C. ISO Cap nut and Screw mount only) | |||
6.Pressure Port Type/Size | F1 | ISO Ferrule 1.5S | ||
F2 | ISO Ferrule 2S | |||
F3 | ISO Ferrule 2.5S[Make to order] | |||
F4 | ISO Ferrule 3S[Make to order] | |||
F6 | ISO Ferrule 4S[Make to order] | |||
V50A | VARIVENT® DN50[Make to order] | |||
V65A | VARIVENT® DN65[Make to order] | |||
V80A | VARIVENT® DN80[Make to order] | |||
V100A | VARIVENT® DN100[Make to order] | |||
R1 | ISO Cap nut 1.5S[Make to order] Hexagon nut included | |||
R2 | ISO Cap nut 2S[Make to order] Hexagon nut included | |||
M0 | Screw mount type simple substance Dedicated O-ring included (×1) | |||
M1 | JIS20K50A With flange, Dedicated O-ring included (×1) | |||
M2 | JIS20K80A With flange, Dedicated O-ring included (×1) | |||
7.Pressure Port Material | Blank | SUS316L, Electro-Chemical Buffing(Ry0.7) ⑤Supports all rated capacities. ⑥Supports all pressure port type/size. | ||
HS1 | Hastelloy C276, Electro-Chemical Buffing(Ry0.7) ⑤Rated capacitor can be selected from among 300, 500 and 1000kPa. ⑥Pressure port type/size can be selected from among F1, F2, F3 and M0. | [Make to order] Negative pressure and compound pressure are not supported | ||
J4L | SUS329J4L, Buffing(#400) ⑤Rated capacitor can be selected from among 300, 500 and 1000kPa. ⑥Pressure port type/size can be selected from among F1, F2, F3 and M0. | |||
8.Limitation | P | 400%R.C.(3MPa is not selectable) | ||
Blank | 150%R.C.(3MPa only) | |||
9.Power | 4 | DC24V(±10%) [200mA] | ||
7 | AC90~240V [6VA] |
(*2) Basically the calibration range is within the rated capacity, but other requirements are possible, as long as the range is 50% or more than the rating of the sensor used.